Agilent 8570A 10 MHz to 22 GHz Microwave Spectrum Analyzer

Agilent 8570A

10 MHz to 22 GHz Microwave Spectrum Analyzer

  Price Item Seller Buy it

Specs

Product Description:

Agilent 8570A 10 MHz to 22 GHz Microwave Spectrum Analyzer

Agilent 8570A

The Agilent 8570A spectrum analyzer is a wide band, very sensitive receiver. It works on the principle of "super-heterodyne receiver" to convert higher frequencies (normally ranging up to several 10s of GHz) to measurable quantities. The received frequency spectrum is slowly swept through a range of pre-selected frequencies, converting the selected frequency to a measurable DC level (usually logarithmic scale), and displaying the same on the CRT of the Agilent 8570A. The CRT displays received signal strength (y-axis) against frequency ( x-axis).

Some applications for Agilent 8570A Spectrum Analyzers include Site Monitoring: Verify that the frequency and signal strength of your transmitter is accurate. Interference: Before a system is installed you use a Agilent 8570A spectrum analyzer to verify that the frequencies (you plan to use) are not occupied or if the presence of a very strong signal will interfere with your new setup. Interference can be created by a number of different situations. Other tests that utilize the Agilent 8570A spectrum analyzer features include antenna isolation, co-channel interference, adjacent channel power, occupied bandwidth, intermodulation, microwave or satellite antenna alignment, and characterization of components.

Wide Resolution, 100Hz~3MHz
Simple 3 knob operation
Digital display dual traces
Direct plotter output

Performance Characteristics of the 8570A

Form Factor Benchtop
Input Impedance 50 Ohm
Minimum Frequency 10 MHz
Maximum Frequency 22 GHz
Zero Span No
Minimum Span 1.7 Hz
Maximum Span 22 GHz
Minimum Sweep Time 2 us
Maximum Sweep Time 10 s
Minimum Resolution Bandwidth 1 kHz
Maximum Resolution Bandwidth 3 MHz
Resolution Bandwidth Steps 1/3/10
Maximum Single-Side-Band Noise 70 dBc/Hz
Maximum Safe AC Input 30 dBm
Minimum Displayed Average Noise -110 dBm
Maximum Displayed Average Noise -85 dBm
Maximum Amplitude Uncertainty 0.183333333333333 %
Connector type (main signal) Type-N(f)
Probe Power No
Noise Source Driver No

Programmability/Connectivity of the 8570A

User Interface Proprietary
Ports to Peripheral Devices HPIB

8570A Compliance

CE Compliance Compliant
UL Compliance Not compliant

8570A Power Requirements

Input Power Universal (Auto Sense and Switch)

8570A Physical Dimensions

  • Width:
  • Height: (N/A)
  • Length: (N/A)
  • Weight: 26.8 kg(59.08 lb)