Agilent 6628A DC power supply, 2 precision dual ranging outputs. 16/50 Vdc. 50 W per output.
| Form Factor |
Benchtop |
| No. of Outputs |
2 o/p |
| Range programming modes |
Fixed |
| Output 1 Max. power |
50 Watts |
| Output 1/Range 1 Max. Current |
0.2 A (0 V to 16 V) |
| Output 1/Range 2 Max. Current |
1 A (0 V to 50 V) |
| Output 1/Range 3 Max. Current |
2 A (0 V to 16 V) |
| Output 2 Max. power |
50 Watts |
| Output 2/Range 1 Max. Current |
0.2 A (0 V to 16 V) |
| Output 2/Range 2 Max. Current |
1 A (0 V to 50 V) |
| Output 2/Range 3 Max. Current |
2 A 16 V |
| Voltage Programming Accy Output1/Range1 |
0.0001875 % |
| Current Programming Accy Output1/Range1 |
0.000925 % |
| Voltage Programming Accy Output1/Range2 |
0.0002 % |
| Current Programming Accy Output1/Range2 |
0.0025 % |
| Voltage Programming Accy Output2/Range1 |
0.0001875 % |
| Current Programming Accy Output2/Range1 |
0.0925 % |
| Voltage Programming Accy Output2/Range2 |
0.0002 % |
| Current Programming Accy Output2/Range2 |
0.0005 % |
| Voltage Ripple and Noise |
500 uV |
| Current Ripple and Noise |
0.1 mA |
| Load Regulation, Voltage |
0.5 mV |
| Load Regulation, Current |
0.01 mA |
| Load Cross Regulation, Voltage |
0.25 mV |
| Load Cross Regulation, Current |
0.01 mA |
| Line Regulation, Voltage |
0.5 mV |
| Line Regulation, Current |
0.01 mA |
| Transient Response Time |
75 us |
| Programming Response Time |
6 ms |
| Programming Resolution (% of full scale) |
0.03 % |
| Remote Sensing Measurement |
Yes |
| Multiple Unit Combinations |
Parallel,Series |
| Overvoltage Protection |
Yes |
| Overcurrent Protection |
Yes |
| Over-temperature Protection |
Yes |
| Local Lockout |
Yes |
| Calibration security |
Jumper |
| Self test |
Yes |