Product Description:
Agilent E3642A DC power supply, dual range: 0-8V/ 5A and 0-20V/ 2.5A, 50 W. GPIB, RS-232
Data sheet (PDF)
30W Single Output, DUal Range
SCPI Compatible
Low Noise And Excellent regulation
Front & Rear Output Terminals
Highly Visible Vacuum flourescent displa
Rear output and sense terminals
Remote Sensing: 1V
More information from Agilent
Performance Characteristics of the E3642A
| Form Factor |
Benchtop |
| No. of Outputs |
1 o/p |
| Output 1 Max. power |
50 Watts |
| Output 1/Range 1 Max. Current |
5 A (0 V to 8 V) |
| Output 1/Range 2 Max. Current |
2.5 A (0 V to 20 V) |
| Voltage Programming Accy Output1/Range1 |
0.00125 % |
| Current Programming Accy Output1/Range1 |
0.02 % |
| Voltage Readback Accy Output1/Range1 |
0.000625 % |
| Voltage Ripple and Noise |
0.5 mV |
| Current Ripple and Noise |
4 mA |
| Load Regulation, Voltage |
3 mV |
| Load Regulation, Current |
250 uA |
| Line Regulation, Voltage |
3 mV |
| Line Regulation, Current |
250 uA |
| Programming Resolution (% of full scale) |
0.000625 % |
| Remote Sensing Measurement |
Yes |
| Overvoltage Protection |
Yes |
| Overcurrent Protection |
No |
| Over-temperature Protection |
No |
| Local Lockout |
No |
| Self test |
No |
Programmability/Connectivity of the E3642A
| User Interface |
Proprietary
|
| Ports to Peripheral Devices |
GPIB,RS232
|
E3642A Compliance
| CE Compliance |
Compliant
|
| UL Compliance |
Not compliant
|
| Safety Issue |
UL3111-1 certified to CSA 22.2 No. 1010.1 conforms to IEC 1010-1; complies with EMC directive 89/336/EEC(Group1, Class A)
|
E3642A Power Requirements
E3642A Physical Dimensions
- Width: (N/A)
- Height: 103.6 mm(4.07 in)
- Length: 374 mm(14.72 in)
- Weight: 6.2 kg(13.66 lb)