Agilent Technologies Inc. 8711C 300 kHz to 1.3 GHz Scalar Network Analyzers

Agilent Technologies Inc. 8711C  

300 kHz to 1.3 GHz Scalar Network Analyzers

  Price Item Seller Buy it

Specs

Product Description:

Agilent Technologies Inc. 8711C 300 kHz to 1.3 GHz Scalar Network Analyzers

Agilent Technologies Inc. 8711C

Data sheet (PDF)

The Agilent Technologies Inc. 8711C network analyzer is an instrument which measures the complex transmission and reflection characteristics of two-port devices in the frequency domain. It does this by sampling the incident signal, separating the transmitted and reflected waves, and then performing ratios that are directly related to the reflection and transmission coefficients of the two-port. Frequency is swept to rapidly obtain amplitude and phase information over a band of frequencies of interest.

Agilent Technologies Inc. 8711C network analyzers utilize synthesized-frequency sources to provide a known test stimulus that can sweep across a range of frequencies or power levels. Agilent Technologies Inc. 8711C network analyzers also can perform ratioed measurements (including phase), which require multiple receivers. The Agilent Technologies Inc. 8711C can provide a wealth of knowledge about a device under test (DUT), including its magnitude, phase, and group-delay response.

Sweep speed 50 ms
8 markers per channel
Narrowband & Broadband
9" VGA display
Linear+Log+Group delay+phase
SWR, polar, Smith Chart
AM delay and fault location
2,6,12 port switching test set
Output Accuracy : 1dB

Performance Characteristics of the 8711C

Form Factor Benchtop
Type Scalar
Integral Signal Source Yes
Integral Test Set T-R Parameter
Source Minimum Frequency 300 kHz
Source Maximum Frequency 1.3 GHz
Source Frequency Resolution 1 Hz
Source Frequency Accuracy 0.0005 %
Minimum Output Power 0.001 Watts
Maximum Output Power 19.9526 mW
Output Accuracy 1 dB
Output Impedance 50 Ohm
No. of Receiver Channels 1 ch
Receiver Minimum Frequency 300 kHz
Receiver Maximum Frequency 1.3 GHz
Minimum Dynamic Range 60 dB
Maximum Dynamic Range 100 dB
Maximum Input Decibel 10 dBm
Input Connector Type Type-N(f)

Programmability/Connectivity of the 8711C

User Interface Proprietary
Ports to Peripheral Devices HPIB
Data Storage Type FDD,HDD

8711C Compliance

CE Compliance Not on file
UL Compliance Not compliant

8711C Power Requirements

Input Power Universal (Auto Sense and Switch)

8711C Physical Dimensions

  • Width: (N/A)
  • Height: 179 mm(7.04 in)
  • Length: 514 mm(20.23 in)