Agilent Technologies Inc. 54122A

Agilent Technologies Inc. 54122A

12.4GHz four-Channel test set

Product Description:

Agilent Technologies Inc. 54122A 12.4GHz four-Channel test set

Agilent Technologies Inc. 54122A

The Agilent Technologies Inc. 54122A oscilloscope is a graph-displaying device – it draws a graph of an electrical signal. In most applications, the graph shows how signals change over time: the vertical (Y) axis represents voltage and the horizontal (X) axis represents time. The intensity or brightness of the display is sometimes called the Z axis.

The Agilent Technologies Inc. 54122A oscilloscope's simple graph can tell you many things about a signal, such as: the time and voltage values of a signal, the frequency of an oscillating signal, the “moving parts” of a circuit represented by the signal, the frequency with which a particular portion of the signal is occurring relative to, other portions, whether or not a malfunctioning component is distorting the signal, how much of a signal is direct current (DC) or alternating current (AC) and how much of the signal is noise and whether the noise is changing with time.

INTERNAL ATTENUATION
5% REFLECTION
TRIGGERED MODE
FREE RUN MODE
HIGH FREQ REJECT

Performance Characteristics of the 54122A

Form Factor Module (proprietary interface/bus)
Bandwidth 12.4 GHz
Number of Channels 4 ch
Simultaneous Channels 4 ch
Min. Vertical Sensitivity 1 mV/div
Maximum Vertical Sensitivity 80 V/div
Rise time 28.2 ps
Number of Bits 12 bits
Input Impedance (alternate) 50 Ohm
Maximum Input Voltage 5 Vrms
Main time base - lowest .01 ns/div
Main time base - highest 1 s/div
Timebase accuracy 0.1 %
Trigger Source External,Internal
Minimum Trigger Holdoff 16 ns
Trigger Sensitivity 40 mV

Programmability/Connectivity of the 54122A

User Interface Proprietary

54122A Compliance

CE Compliance Not on file
UL Compliance Compliant

54122A Power Requirements

Input Power USA (110V/60Hz)

54122A Physical Dimensions

  • Width: (N/A)
  • Height: 105 mm(4.13 in)
  • Length: 432 mm(17 in)
  • Weight: 2 kg(4.4 lb)

Options for 54122A

Option US List Price
908 / RACKMOUNT FLANGE KIT Discontinued
910 / Additional operating and service manual Discontinued
W30 / 3 Years Return for Repair Service Discontinued
W32 / 3 Years Return for Calibration Service Discontinued
W34 / 3 year Customer Return Standard Compliance Calibration Service Discontinued
W50 / 5 Year Customer Return Repair Service Discontinued
W52 / 5 Years Return for Calibration Service Discontinued
W54 / 5 Years Return for Calibration Service Discontinued

54122A Standard Accessories

  • 0960-0055 /COAXIAL SHORTS /Qty:5
  • 1250-1200 /SMA(m) TO BNC(f) ADAPTERS /Qty:2
  • 5061-5311 /ADAPTERS APC-3.5 /Qty:5
  • 8120-4948 /50 OHM CABLES SMA /Qty:3
  • 9300-1484 /ANTI STATIC MAT,STRAP /Qty:1
  • HP 54118A /18GHZ TRIGGER /Qty:1
  • HP54007A /RF ACCESSORY KIT /Qty:1

More Agilent Technologies Inc. savings