Leader LS8106

Leader LS8106

Oscilloscope, Analog: 100MHz, 3 Channels With CRT Readout

Product Description:

Leader LS8106 Oscilloscope, Analog: 100MHz, 3 Channels With CRT Readout

Leader LS8106

The Leader LS8106 oscilloscope is a graph-displaying device – it draws a graph of an electrical signal. In most applications, the graph shows how signals change over time: the vertical (Y) axis represents voltage and the horizontal (X) axis represents time. The intensity or brightness of the display is sometimes called the Z axis.

The Leader LS8106 oscilloscope's simple graph can tell you many things about a signal, such as: the time and voltage values of a signal, the frequency of an oscillating signal, the “moving parts” of a circuit represented by the signal, the frequency with which a particular portion of the signal is occurring relative to, other portions, whether or not a malfunctioning component is distorting the signal, how much of a signal is direct current (DC) or alternating current (AC) and how much of the signal is noise and whether the noise is changing with time.

One-Touch Auto Setup Sets V Sensitivity and Time Base
Continuous On-Screen Readout of Frequency and Vp-p or DC Level for CH1
On-Screen Readout of H&V Scale Factors, Coupling, Uncal, INVert, ADD, MAG, X-Y and Delay Line
Cursor Measurements of (DV, DT, DV%,DT%, 1/DT )
Frequency and Phase 100-MHz Bandwidth
Calibrated Delayed Sweep
Alternate Sweep - Shows Main and Delayed Waveforms Simultaneously
3-Channel, 8-Trace Operation CH1, CH2, CH3,
CH1 + CH2 Main and Delayed
400 V (dc ± ac peak) Input Withstand (CH1 and CH2)
FIXed Trigger Mode Ensures Stable Triggering Despite Wide Amplitude Swings
Dedicated TV-V and TV-H Sync Separators for Rock
Solid Video Waveforms
Variable Holdoff for Correct Display of Complex Wavetrains
Single Sweep Operation
X-Y Operation
2% V Accuracy
1 mV/div Sensitivity with 20-MHz Band Limit
5 ns/div Sweep Speed with X10 Mag
Signal Delay (All Channels) Ensures View of Trigger Edges
CH1 Output Makes CH1 Amplifier Available as a High Gain Calibrated Preamp
Z-Axis (Intensity Modulation)

Performance Characteristics of the LS8106

Form Factor Benchtop
Bandwidth 100 MHz
Rise time 3.5 ns
Number of Channels 3 ch
Min. Vertical Sensitivity 1 mV/div
Maximum Vertical Sensitivity 5 V/div
Vertical(or Deflection Factor) Accuracy 2 %
Input Coupling AC,DC,GND
Input Impedance 1 MOhm
Maximum Input Voltage 400 V(dc+p
Main time base - lowest 50 ns/div
Main time base - highest 500 ms/div
B Sweep Time Base (low) 50 ns/div
B Sweep Time Base (high) 50 ms/div
Time base Magnification factor (X?) x10
Timebase accuracy 3 %
Trigger Source External,Internal
Trigger Modes Alternate,Auto,Normal,Single
Trigger Sensitivity 1 mV
Display Type CRT Monochrome
Display Size 12.7 cm

Programmability/Connectivity of the LS8106

User Interface Not Applicable

LS8106 Life Cycle Data

Out of Production Jun-01-2002

LS8106 Compliance

CE Compliance Not on file
UL Compliance Not compliant

LS8106 Power Requirements

Input Power Universal (Auto Sense and Switch)

LS8106 Physical Dimensions

  • Width: (N/A)
  • Height: 150 mm(5.9 in)
  • Length: 400 mm(15.74 in)
  • Weight: 8.7 kg(19.18 lb)

LS8106 Standard Accessories

  • LP-103 /Probes /Qty:2
  • LS 8106_Fuse /Spare Fuse /Qty:1
  • LS 8106_Screwdriver /Adjusting Screwdriver /Qty:1